• Home
  • About company
    • Certification
  • Representative
    • ZEZ SILKO
    • SEMICONDUCTORS
  • Controllers (PFC) KMB
    • NOVAR 1005 - 1007
    • NOVAR 1106 - 1114
    • NOVAR 1206 - 1214
    • NOVAR 1312
    • NOVAR 2100
    • NOVAR 2200
    • NOVAR 2400
    • NOVAR 2600
    • NOVAR 2700
    • KATKA 12 ST
    • KATKA 20 D
    • KATKA 20 ST
    • KATKA 20 T
    • KATKA 80 D
    • KATKA 80 T/ST
  • Thyristors, Diodes
    • THYRISTORS
    • DIODES
    • MODULES
    • IGBT
  • Download
  • Contacts

Products BGENGRUS

Power capacitors 
Low voltage power capacitors
Medium voltage power capacitors
Controllers (PFC) KMB System 
NOVAR 1005 - 1007
NOVAR 1106 - 1114
NOVAR 1206 - 1214
NOVAR 1312
NOVAR 2100
NOVAR 2200
NOVAR 2400
NOVAR 2600
NOVAR 2700
KATKA 12 ST
KATKA 20 D
KATKA 20 ST
KATKA 20 T
KATKA 80 D
KATKA 80 ST/T

Induction heating capacitors 
Induction heating up to 1 000 kVAr,6 kHz
Induction heating up to 2 000 kVAr,4 kHz
Induction heating up to 2 500 kVAr,4 kHz
Induction heating up to 8 000 kVAr,8 kHz
Induction heating up to 5 000 kVAr,5 kHz
Induction heating up to 6 000 kVAr,4 kHz
Induction heating up to 70 kHz, COAX
Induction heating up to 200 kHz MIDICOAX
Induction heating up to 5 000 kVAr, 120 kHz
Induction heating up to 6 000 kVAr, 10 kHz
Capacitors for power electronics 
DC link (filtering) capacitors
AC filter capacitors
Snubber capacitors for IGBT
Snubber capacitors for SCR and GTO
HV capacitors for general purposes
Ripple control coupling capacitors
Surge capacitors (medium voltage)
Commutating capacitors
Energy storage (impuls) capacitors 
Capacitor banks 
Components for PFC 
Contactors for capacitors
Reactors
High voltage transformers
Thyristors, Diodes, Modules, IGBT

 

 

 


 


 

 

 

POWER FACTOR REGULATORS

NOVAR 1312

Real-time (fast) single- and three-phase PFC

NOVAR 1312 and NOVAR 1312-3 power factor controllers are fully automatic controllers for dynamic compensation systems. It can control fast thyristor switched capacitor banks for real-time response to changes of power factor. Its processor and algorithm allows up to 25 control interventions in one second. Together with KATKA thyristor switching modules it provides perfect control of fast PFC cabinet.

The controller can also be used in combined systems where both KATKA thyristor switching modules and classical electromechanical contactors are used together. Optional RS-485 communication port allows to monitor all measurement values and set instrument parameters using a remote PC.

NOVAR 1312-3 is a special option with 3 independent current inputs. It measures sum of all three current signals instead of just one. Therefore, it allows compensation according to a more relevant three-phase power factor under unbalanced conditions. For a full-featured three-phase power factor controller see the NOVAR 2700 and other NOVAR 2000 products.

NOVAR_1312
Key features
      • up to 25 control intervention per second
      • 12 transistor switched outputs and 2 conventional relay outputs + alarm
      • up to 14 outputs and 1 alarm relay
      • compatible with KATKA Thyristor Switching Modules
      • allows combined compensation systems for both thyristor switching modules and mechanical contactors
      • optional supply voltage up to 500 V (/S400 models)
      • automatic setup and simple configuration
      • precise measurement and control functions under distortion
      • evaluation of total harmonic distortion
      • evaluation of current harmonic load for capacitor protection
      • built-in temperature sensor
      • optional alarm or cooling/heating control relay

NOVAR_1312-2 


 
Shandor Ltd., Plovdiv, Bulgaria, e-mail: shandor(at)gbg.bg,   tel.: +359 898 528828, fax: +359 32 644878